Brass Knob
Wednesday, September 14th, 2011Brass Knob
![]() |
![]() American Heat 16 KW Whole House Tankless Water Heater US $269.00
|
![]() Oil Rubbed Bronze Handleset Right Hand Lever 8521 R46 US $44.95
|
![]() Satin Nickel Handleset Right Hand Lever 8521 R46 SN US $39.95
|
![]() Bath High Heel Design 45 64 Water Outlet Wash Basin Faucet US $26.23
|
![]() Brand New Amerock Fine Porcelain Door Knobs Lot of 8 US $145.00
|
![]() Passage Antique Brass Lever Door Knob Lock knobs US $8.79
|
![]() 1 1 4 125 Provincial Solid Cast Round POLISHED BRASS KNOBS PULLS Qty 30 US $39.99
|
![]() Brass Shower Valve with Copper Faucet set US $50.00
|
![]() 25 Burnished Brass Pull Kitchen Cabinet Hardware 375cen US $29.50
|
![]() 12 Glass Cabinet Knobs Cupboard Drawer Pulls Handles K30 US $26.99
|
![]() 8 Glass Cabinet Knobs Vintage Style Drawer Pulls K3 US $15.99
|
![]() BOX OF 25 Antique Satin Brass Square Cabinet Knobs RK 81091 US $49.95
|
![]() Schlage Inside Handleset Inside Door knobDeadbolt BRASS F59FLA 605 NEWLEFT DR US $20.99
|
![]() 8 Glass Cabinet Knobs Victorian Style Kitchen Drawer Pulls Hardware VIC US $10.99
|
| The Home Improvement Helper |
Light switches with knob and tube wiring?
I've replaced all of my light switches in my VERY OLD house over the past few days with new switches. There is original knob and tube wiring going to most of them. I haven't had any problems until I replaced a light connected to 2 switches. The hall light at the top of my stairs is connected to a switch downstairs and a switch upstairs. One switch has 4 wires going to it and the other has 3 wires. Both new switchs are 2-way switches and have brass and copper connections on the right and brass and green connections on the left. Any ideas on how they should be hooked up?? I've re-wired them several times but can't get them working together. Either one switch works at a time or neither work.
actually i think they are 3-way switches. they're the ones that don't say on/off on them
Typical 3way switching consists of 2 switches. one switch is fed hot all the time by the power source. There must be 2 unbroken wires between each switch. (travellers). . The other switch accepts those 2 travellers. The third terminal on the opposing switch is for the switch leg conductor. This goes directly to the light fixture hot lead..
So..we have one three way switch with a hot and 2 travellers under the three screws. the other has the 2 travellers and the switch leg... its the only way its gonna work...you may have to take an ohmeter and "prove" your travellers at each switch. TURN OFF POWER FIRST!!!
Now, if we wanted a switch in between our 2 3ways, we would break our travellers (2 wires) thru a 4-way switch..
OK, your situation...4 wires at one switch, 3 at the other. Is there another 3 way in the lite switching layout? If so, you are working on a 4way and a 3 way switch...
If this is not the case, then you may have some head scratching to do...The old-timers used to get really creative with the old K&T wire, especially when it came to switching..and forget equipment grounds, cause they were nonexistent then..
Remember, it must start and end with a 3 way switch...you could put 100 4way switches in between ..Also on your new switches, there will be 2 "like colored" screws and one a bit different. the travellers go under the 2 like screws..Very Important!!Good Luck!!!


US $76.95